跳至主要内容

ELISA Assay Development

 

Principles

The Enzyme-Linked ImmunoSorbent Assay, or ELISA, is a technique used to detect the presence of a specific molecule in a given sample. The molecule to be detected could be an antibody or antigen.
Basically, a small plastic well is coated with an antibody that binds to the antigen of interest (for example, a toxin). Sample is added to the well. If the toxin is present, it binds to the antibody and sticks to the well surface. The samples are rinsed to remove any unbound material. Another anti-toxin antibody is added. Then a tagged antibody is added; this one has an enzyme attached to one end. The substrate of the enzyme is then added. If the enzyme is there, the substrate gets converted to a colored product, and we can see it as a positive result.

Procedure

  1. The surfaces of the wells in the plate are coated with a “capture” antibody.
  2. The sample is then added and any antigen present binds to the capture antibody. After washing the plates, only the antibody-antigen complexes remain attached to the well.
  3. A second antibody (“detecting” antibody) which will bind to any antigen-antibody complexes is added to the wells.
  4. An enzyme-linked secondary antibody is added. This antibody recognizes the detecting antibody.
  5. After washing the plates again, all the excess antibody will be removed. Finally a substrate that reacts with the enzyme is added to provoke a chromogenic or fluorescent signal. Positive reactions are detected by color in the wells.

Elisa Advantages

  • Versatile: Many systems using different combinations of reagents can be used. Allows passive immobilization of reagents to a solid phase and easy separation of bound/unbound reactants using washing steps.
  • Simple: Multiple samples can be tested in a variety of formats using microtiter plates and compatible equipment that provides high capacity, rapid and inexpensive assays feasible to kit development.
  • Sensitive: Readouts come from enzyme catalysts or fluorescent tags that amplify signal efficiently and provide range of detection optimal for critical assays including diagnostics.
  • Quantitative: Signal is detected by multichannel spectrophotometers and therefore the collected data can be stored and analyzed statistically.

Elisa Disadvantages

  • The most important disadvantage in the ELISA for cholera toxin is the cross reaction that it displays with other similar toxins. Specifically this technique shows cross reactivity with heat-labile toxin from E. coli.
  • The technique requires some additional reactions and equipment (ELISA lector) that could make it expensive.

The enzyme linked immunosorbent assay (ELISA) is used for the detection and quantification of proteins typically secreted or released from cells. Immobilizing a target-specific capture antibody onto a high protein binding capacity ELISA plate enables capture of target protein. The captured protein is then detected by a protein-specific biotinylated antibody. The target protein is quantified using a colorimetric reaction based on activity of avidin-horseradish peroxidase on a specific substrate. The optical density of the end-product is measured using a spectrophotometer. eBioscience offers a variety of ELISA to cytokines, chemokines,growth factors and protein released upon cell death.

Types of ELISA (Direct, Indirect, Sandwich, Competitive)

1. Direct Assay: It is the simplest configuration in which the antigen is bound by passive adsorption to the solid phase, washed to remove any unbound molecules and then directly incubated with a conjugated antibody. Following the incubation period and additional washing, substrate is added to produce signal that is allowed to develop. After certain time, the substrate reaction is stopped and the resulting signal quantified. It is commonly used for tittering conjugated secondary antibodies and very useful to estimate antigen cross-reactivity.

  • elisa advantages and disadvantagesPure antigen coated on plate walls
  • Enzyme-linked antibody added to wells; binds to antigen
  • Substrate added for color change
  • Fast and simple
AdvantagesDisadvantages
Faster than other ELISA – the technique has fewer stepsAntigen immobilization is not specific – may cause higher background noise than indirect ELISA. Mainly because all proteins in the sample, including the target protein, will bind to the plate
Less flexible – each target protein needs a specific conjugated primary antibody
No signal amplification – reduces assay sensitivity
Less prone to error – as less reagents and fewer steps are required
Best for: when analyzing the immune response to an antigen.

2. Indirect Assay: In this system, initial antigen binding and washing steps are the same as the direct method. The main difference in this case is the use of unconjugated antibody to bind the immobilized antigen upon incubation at optimal temperature (usually 37⁰C). Following a washing step to remove unbound antibodies, the remaining antigen-bound antibodies are targeted by a conjugated secondary antibody that will generate the readout signal as described for direct ELISA. This system has been widely applied in diagnostics because it allows large number of samples to be screened with a single conjugated secondary antibody.

Indirect Elisa Assay

  • Pure antigen coated on plate walls
  • Sample containing 1°antibody added
  • 2°antibody bound to enzyme is added to bind to 1°antibody
  • Increased sensitivity
AdvantagesDisadvantages
High sensitivity – more than one labeled secondary antibody can bind the primary antibodyPossibility of background noise – secondary antibody may be cross-reactive
Longer procedure than direct ELISA technique – additional incubation step for secondary antibody needed
Economical – fewer labeled antibodies are needed
Greater flexibility – different primary antibodies can be used with a single labeled secondary antibody
Best for: determining total antibody concentration in samples.

3. Sandwich Assay: This assay requires a compatible antibody pair that recognize different antigenic targets (epitopes) on the same antigen. The first antibody, called capturing antibody, is coated on the plate and used to immobilize the antigen upon binding during incubation with the sample. Free antigen is removed by a washing step and then a detecting antibody is added to bind the captured antigen and enable subsequent detection.

Sandwich Assay

  • Capture antibody immobilized on plate walls
  • Sample containing antigen binds to capture antibody
  • 1°antibody added, binds to antigen, creates a “sandwich”
  • 2°antibody linked with enzyme binds to primary antibody
  • High sensitivity; two antibodies bind to antigen
  • Suitable for complex samples;antigen doesn’t require purification
AdvantagesDisadvantages
High sensitivity – 2-5 times more sensitive than direct or indirect ELISAAntibody optimization can be difficult – cross-reactivity may occur between the capture and detection antibodies. Needs a standardized ELISA kit or tested antibody pair.
High specificity – two antibodies are involved in capture and detection
Flexibility – both direct and indirect detection can be used
Best for: analysis of complex samples, since the antigen does not need to be purified prior to measurement.

4. Competitive Assay: Each of the core systems described above can be further modified to measure molecules based on their ability to interfere with a well-known pre-titrated assay. Such assays can be used to study either antigens or antibodies and they can be competitive or inhibitory based on the specific conditions of each assay. In both types of assays, a pre-titrated system is challenged with the presence of the testing sample whose binding activity is then determined from the degree of the resulting interference in the established system.

  • Competitive AssayPurified antigen coated on plate walls
  • Sample containing unknown antigen added
  • If both bound and free antigens are identical,will compete with each other to bind to the antibody
  • Decrease in signal = high antigen concentration
AdvantagesDisadvantages
Main advantage – no sample processing is required and crude or impure samples can be usedSame limitations as base ELISA – as each ELISA technique can be adapted to a competitive format
More robust – less sensitive to sample dilution and sample matrix effects than the sandwich ELISA
More consistent – less variability between duplicate samples and assays
Maximum flexibility – it can be based on direct, indirect or sandwich ELISA
Best for: commonly used when only one antibody is available for the antigen of interest. It is also suitable for detecting small antigens that cannot be bound by two different antibodies such as in the sandwich ELISA technique.

Related Articles:

Elisa Assay Services of Medicilon

Ligand Binding Assay

评论

此博客中的热门博文

Medicilon and Binhui Biopharmaceutical Have Reached a Strategic Collaboration to Jointly Draw a New Blueprint for the Development of New Biological Drugs

  On March 18, Medicilon and Binhui Biopharmaceutical (Binui Bio) announced a strategic collaboration.  The two parties will work together to jointly explore the possibilities in cutting-edge fields such as oncolytic viruses, nucleic acid drugs and protein drugs. Gather and Work Together to Create Advantages      Facilitate the Research and Development of Oncolytic Viruses, Nucleic Acids, Proteins and Other Drugs As a one-stop biopharmaceutical comprehensive preclinical R&D service CRO, Medicilon has been developing and accumulating for 20 years, always adhering to the spirit of innovation, and has successfully constructed bi/multi-specific antibodies,  ADCs ,  mRNA vaccines ,  small nucleic acid drugs ,  PROTAC , and  CGT technical service platform  that have helped 421 INDs obtain clinical approval.  It is this outstanding achievement that has earned Medicilon wide recognition in the industry and laid a solid foundation f...

A Nickel-Catalyzed Reductive Alkylation of Aryl Bromides and Chlorides for Sp3-Sp2 Bond Formation

  In 2012, a nickel-catalyzed reductive alkylation method of aryl bromides and chlorides was reported. Under the optimized conditions, a variety of aryl and vinyl bromides as well as active aryl chloride can be reductively coupled with alkyl bromides in high yields. The protocols were highly functional-group tolerant and the reactions were not air or moisture sensitive. The reaction showed different chemoselectivity than conventional cross-coupling reactions. Substrates bearing both anelectrophilic and nucleophilic carbon resulted in selective coupling at the electrophilic carbon (R-X) and no reaction occurred at the nucleophilic carbon (R-[M]). The 2010 Nobel Prize in Chemistry was awarded for the Pd-catalyzed cross-coupling, and in the past decade the progress in cross-coupling has not only had a significant impact on academic research but has also influenced the industrial synthetic application. The transition-metal-catalyzed union of nucleophilic organo-boronic acids with elect...

What is Toxicokinetics?

Toxicokinetics  is essentially the study of “how a substance gets into the body and what happens to it in the body”. Four processes are involved in toxicokinetics. The study of the kinetics (movement) of chemicals was originally conducted with pharmaceuticals and thus the term pharmacokinetics became commonly used. In addition, toxicology studies were initially conducted with drugs. However, the science of toxicology has evolved to include environmental and occupational chemicals as well as drugs. Toxicokinetics is thus the appropriate term for the study of the kinetics of all toxic substances. Frequently the terms  toxicokinetics ,  pharmacokinetics , or disposition may be found in the literature to have the same meaning. Disposition is often used in place of toxicokinetics to describe the time-course of movement of chemicals through the body (that is, how does the body dispose of a xenobiotic?). The disposition of a toxicant along with its’ biological reactivi...